HV-GATE SERIES 11 | |||||||
Technical Data | DN63 | DN80 | DN100 | DN160 | DN200 | DN250 | DN320 |
Leak rate: Valve body, Valve seat | < 1 x 10-9 mbar ls-1 | ||||||
Pressure range | 1 x 10-8 mbar to 1.6 bar (abs) | 1 x 10-8 mbar to 1.2 bar (abs) | |||||
Differential pressure on the gate | ≤ 1.6 bar | ≤ 1.2 bar | |||||
Differential pressure at opening | ≤ 30 mbar | ||||||
Cycles until first service | 200 000 | ||||||
Material | |||||||
– Valve body | AISI 304 (1.4301) | ||||||
– Mechanism | AISI 316L (1.4404) | AISI 304 (1.4301) | |||||
– Bellows | AISI 633 (AM350) | ||||||
Seal: bonnet, Gate | FKM (Viton®) | ||||||
Feedthrough | Balg | ||||||
Solenoid valve | 24 V DC, 2.5 W (others on request) | ||||||
Position indicator: contact rating | |||||||
– Voltage | 10 – 30 V DC | ||||||
– Current | Max. 200mA | ||||||
Valve position indicator | LED |
HV-GATE SERIES 11
- General purpose valve for isolation in high vacuum systems
- Especially suited to pump isolation
Benefits
- Low-cost bellows sealed valve
- DN 63 – 200 with vulcanized seal (no dead volumes at the gate seal)
Accessories
- Seals
- Heater
- Connection elements